6
Quick-Start
Follow these steps to get the Coloram II Color Changer operational quickly.
1. Connect the equipment
a. Attach the Coloram II Color Changer to a powered light fixture.
b. Connect the Coloram II Color Changer to the power supply using the 4-pin
Wybron Power/Data Cable.
c. Connect the Coloram II (RAM) Power Supply to 115/230 VAC power and
to a DMX source.
2. Setup the Coloram II Color Changer
Set the color changer to an address of 1 as follows:
a. Set the DIP switches as follows:
DIP switch Position
1 motor speed: NORM
2 operation: 24 CHAN
3 channel range: 1-12
4 fan speed: NORM
b. Set the rotary "channel select" switch to 1
3. Setup the Coloram II (RAM) Power Supply
Use the SETUP menu for the following:
a. Set the starting channel to 1.
b. Set the mode to CR2.
4. Send DMX levels
The Coloram II color changer will respond to DMX channel 1. Vary the DMX
level to move the gel string.
Page view 5