Wybron Coloram II User Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 25
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
21
Equipment Compatibility
The following is a chart of compatibility and capacity of the various models of
Coloram power supply and the companion components.
Max # of
Power Supply Model Output Channels Max # of Max # of Max # of Max # of
Description Number Power Available CXI (2) Coloram (3) Eclipse (4) Goboram (5)
6 way 19060 150 watts 12 3 6 6 4
12 way 19012 300 watts 24 6 12 12 8
24 way 19000 600 watts 48 12 24 (1) 24 (1) 16
Notes:
(1) can only use the first 24 channels
(2) CXI’s use 1, 2 or 3 channels
(3) Coloram’s use 1 channel
(4) Eclipse’s use 1 channel
(5) Goboram’s use 3 channels
Cables
Coloram cable
The Coloram cable uses 4-pin XLR connectors on either end and
consists of two 14 AWG conductors and a 22 AWG twisted, shielded
pair. The shells of the two XLR connectors are not electrically
connected together -- this prevents large power currents from flowing
from chassis to chassis of the Coloram equipment. The twisted pair
shield is not connected at either end.
XLR Pin # Wire Color Function Size
1 White 24 Volts DC 14 AWG
2 Green Data - 22 AWG
3 Red Data + 22 AWG
4 Black Ground 14 AWG