Page 32
Head-Feet = [(A)+(A+B)+(A+B+C)+(A+B+C+D)]
= [(100) + (100 + 25) + (100 + 25 + 20) + (100 + 25 + 20 + 25)]
= [100 + 125 + 145 + 170]
= 540 Head-Feet
Since total Head-Feet (540) is less than the maximum (1500), this is a valid
configuration.
DMX Setup and Operation
Controls and Indicators
Nexera LX has controls and indicators as follows:
A three character seven-segment display.
Four push buttons: Menu, (+), (-), and Enter.
Power (red) and signal (green) indicator LEDs.
The seven-segment display shows the address number (1 – 509) and the speed
mode (hi S – lo S). It also displays any error messages, which will be covered in
a later section.
The Menu button allows you to switch between address and mode select.
Pressing the Enter button saves the current address or mode setting before
switching.
The (+) button allows you to increment Nexera LX’s address when in address
mode or toggle between high and low speed in speed mode. Changes are
recorded in non-volatile memory immediately, and the display flashes for 10
seconds to indicate that a change has been made.
The (-) button allows you to decrement Nexera LX’s address when in address
mode or toggle between high and low speed in speed mode. Changes are
recorded in non-volatile memory when the ENTER button is pressed.